Worker nodes appear to have the following hardware:
Component Quantity Model Notes
Motherboard 1 Tyan S5393 (part #S5393WG2NR) Bios revision 1.04b installed (1.05 is available)
Chipset 1 Intel 5400 "Seaburg" chipset with 6321ESB I/O hub  
Processors 2 Intel Xeon E5440 or E5450 Quad-core 2.83GHz on most nodes, 3.0GHz on cloud{3,4,20,22,33,38,48,52,53,63}
Memory 4 4GB DIMMs (16GB total) 667MHz DDR2 Registered, ECC FB-DIMMs
SAS controller 1 LSI SAS 1068E-based controller Onboard/LOM LSISAS1068E, fustion MPT driver (mptsas) Linux driver
Ethernet 1 Intel e1000 dual-port, onboard/LOM
10GigE 1 Qlogic QLE3142-CU-CK (NetXen) dual-port dual-port, PCIe 8x slot
IPMI BMC 1 Likely either Tyan M3295-2 or M3296 Not in use ?? APC power controller and terminal servers duplicate most functionality (though 'reset' rather than power cycle is possible though IPMI and likely not APC)
Hard drives 4 1TB Seagate (ST31000340NS) SATA Connected to LSI 1068E (SAS/STP)
Hardware monitoring
chipset
1 Winbond W83627EHF Super-I/O chip Kernel module w83627ehf
Hardware watchdog
timer
1 Winbond W83627HF Kernel module w83627hf_wdt