Worker nodes appear to have the following hardware:
Component QuantitySorted ascending Model Notes
Motherboard 1 Tyan S5393 (part #S5393WG2NR) Bios revision 1.04b installed (1.05 is available)
Chipset 1 Intel 5400 "Seaburg" chipset with 6321ESB I/O hub  
SAS controller 1 LSI SAS 1068E-based controller Onboard/LOM LSISAS1068E, fustion MPT driver (mptsas) Linux driver
Ethernet 1 Intel e1000 dual-port, onboard/LOM
10GigE 1 Qlogic QLE3142-CU-CK (NetXen) dual-port dual-port, PCIe 8x slot
IPMI BMC 1 Likely either Tyan M3295-2 or M3296 Not in use ?? APC power controller and terminal servers duplicate most functionality (though 'reset' rather than power cycle is possible though IPMI and likely not APC)
Hardware monitoring
chipset
1 Winbond W83627EHF Super-I/O chip Kernel module w83627ehf
Hardware watchdog
timer
1 Winbond W83627HF Kernel module w83627hf_wdt
Processors 2 Intel Xeon E5440 or E5450 Quad-core 2.83GHz on most nodes, 3.0GHz on cloud{3,4,20,22,33,38,48,52,53,63}
Memory 4 4GB DIMMs (16GB total) 667MHz DDR2 Registered, ECC FB-DIMMs
Hard drives 4 1TB Seagate (ST31000340NS) SATA Connected to LSI 1068E (SAS/STP)

Topic revision: r3 - 15 Mar 2010, JasonSommerfield - This page was cached on 25 Apr 2024 - 19:27.

This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.